1.] NC-00 Concentric / Eccentric Type Tapping
Machine Head
-
1.1.) Main specification:
-
1.1.1.) Model:
MODEL
|
Tapping Pad
O.D I.D W.
|
Max.
Cable
O.D.
|
Max.Speed(Rpm)
|
Driven
Motor
(Hp)
|
Metal
|
Non Metal
|
NC-40
|
400
|
75
|
30
|
10mm
|
1400
|
2200
|
NC-50M
|
500
|
75
|
40
|
25mm
|
1000
|
1600
|
Spooler type
|
Custom-design
|
|
1800
|
|
-
1.2.) Features:
-
1.2.1.) Type: Horizontal concentric type helical tapping, one pad per head.
1.2.2.) Application:
1.2.3.) For paper, myler, polyester, mica..non-metal sheet
1.2.4.) For Copper, Aluminum foil..metal sheet
1.2.5.) Tension control: Hysteresis tension brake
1.2.6.) Spare pads holder: 10 pads Max.
1.2.7.) CCCS: Central Computerized Control System.
1.3.) Machine composition:
-
1.3.1.) Tapping head..............................................................1set
1.3.2.) PLC control system.....................................................1set
1.3.3.) Touch screen monitor.................................................1set
1.4.) Remarks:
-
No.50 Lane 573 Ping-Dong Rd., Ping-Zhen City , Tao-Yuan County , TAIWAN , R.O.C. Tel : +886-3-4604789 Fax : +886-3-4604788 E_mail : 1.4.1.) If the above specification differs from that of the quotation or sales contract, according to the quotation or sales contract. No.50 Lane 573 Ping-Dong Rd., Ping-Zhen City , Tao-Yuan County , TAIWAN , R.O.C. Tel : +886-3-4604789 Fax : +886-3-4604788 E_mail : No.50 Lane 573 Ping-Dong Rd., Ping-Zhen City , Tao-Yuan County , TAIWAN , R.O.C. Tel : +886-3-4604789 Fax : +886-3-4604788 E_mail :
-
2.] Detail specifications:
-
2.1.) Tape thickness: Custom-design
2.2.) Tape tension control:
-
2.2.1.) Type: a hysteresis brake mounts in each tape pad, offers precisely tension force during tapping.
2.2.2.) Tension control algorithm : Auto / manual control are switable.Tension is calculated automatically by the Fuzzy-logic control system built in PLC and is proportional to the diameter of the tape-pad during operation.
2.2.3.) Max. tension: Kgs for non-metal tape. Kgs for copper/aluminum foil tape.
2.2.4.) Tape run-out indication : Taping head slow down before running out tape and indication for operator.
2.2.5.) Tape broken detector: Photo sensor type, which activate emergency stop once broken tape detected.
2.2.6.) Guide dies:
-
a.) Inlet side of tapping head complete with guide roller
b.) In front and rear position of tapping tube complete with guide dies.
2.2.7.) Spare pads storage space: 600-1000mm ,custom-design available
2.2.8.) Emergency stop device:
-
a.) Incase of tape broken
b.) Counter length reached
c.) Safety cover opened
2.2.9.) Machine safety house:
-
a.) Type: All-in-one type with two door sliding type.
b.) There are two plastic glass windows on the front side for inside viewing
c.) A fluorescent lamp is provided inside the cover
2.2.10.) Transmission:AC motor + Inverter > timing belt > tapping head. Speed synchronized with main machine
2.2.11.) "CCCS" operation system with Touch screen monitor:
-
a.) Type: "MMI" + "PLC"
b.) Application: Key-in all of the desire data on "MMI" screen, data appears operation situation and faults appear